St Columba Anglican School

School Building Fund

Marketing and communication material from St Columba Anglican School in Port Macquarie

Issue link: http://stcolumba.uberflip.com/i/728916

Contents of this Issue

Navigation

Page 1 of 3

"From little things big things grow" St Columba Anglican School is driven by a vision to create a school that offers an education equal to any in New South Wales, or Australia. Over ten years ago a small group of staff and students saw the realisation of the dream to reintroduce Anglican education to the Hastings. Gathering on the site of St Thomas' Church, they waited for their first buildings on Major Innes Road to be built. Today that small foundation group has grown to over 930 students and over one hundred staff. And what a school we have become, achieving excellent results in all spheres of education we value: Spritual, Cultural, Academic and Sport. Since 2010 the Iona Centre has stood as a symbol of what SCAS can build to foster our students' learning when we have the resources available to us. As a school, we have a record of being able to build excellent buildings, on time and on budget, but we are aware that the type of government funding that made great new resources like the Iona Centre possible, may not always be available to us. We have the vision, the plans and the enormous potential of our students before us. What we need are the resources to achieve this potential. It is a fact that our students' journey to become leaders and lifelong learners can be constrained by our ability to provide the learning spaces they need. We have access to the talents of great teachers and a wonderful environment. We have a culture that applauds and values achievement. We are perched on the edge of greatness. To achieve this greatness we must continue to develop our campus. Stage 13 - Performing Arts Centre In 2016 we will be UP 2 A23 2 A23 3 A22 3 A22 DANCE STUDIO F11 FSVD DANCE STORAGE F13 FCP KEYBOARD LAB F09 FCP STORAGE F10 FCP STAFF ROOM F05 FCP CONTROL ROOM F03 FCP 1 A22 1 A22 Existing Canteen WC F06 FSV2 ACC. WC&SHR F08 FSV2 ACC. WC&SHR F16 FSV2 1 A24 1 A24 3 A23 3 A23 4 A22 4 A22 1 A23 1 A23 STAFF KITCHEN & LOUNGE F04 FCP STORAGE F02 FCP AIRLOCK F07 FSV2 LINE OF BUILDING UNDER A/LOCK F14 FSV1 CORRIDOR F1 F18 FCP 2 A22 2 A22 4 A23 4 A23 COVERED LINKWAY 118 FCS EXISTING IONA CENTRE BALUSTRADE & RETAINING WALL BALUSTRADE BALUSTRADE EXISTING COVERED WAY EXISTING COVERED WAY PAC SCHOOL ENTRY F01 FCP BENCH SEAT BENCH SEAT BALUSTRADE & RETAINING WALL Roof Below EXISTING ROOF EXISTING ROOF LINE OF BUILDING UNDER 2 A24 2 A24 EXIT STAIRS F12 FCS 1 2 3 6 7 4 B C E F G D 5 PLANT AREA - CONC WF 02 DF 01 DF 02 DF 03 WF 08 WF 09 WF 10 WF 11 WF 12 WF 13 WF 14 WF 15 WF 16 WF 17 WF 18 WF 19 WF 20 WF 21 WF 22 WF 27 WF 28 WF 29 WF 30 DF 20 DF 21 DF 19 DF 17 DF 16 DF 15 DF 14 DF 13 DF 12 DF 11 DF 10 DF 09 DF 08 DF 06 DF 07 DF 18 WF 05 WF 06 WF 07 REFER SOUTH-EAST ELEVATION FOR HIGH LEVEL WINDOW NUMBERS ABOVE DOORS WF 32 WF 34 WF 36 FCPM FSV1 WF 38 WF 37 WF 36 WF 35 DF 04 WF 01 WF 03 PLANT ACCESS WALKWAY REFER EAST ELEVATION FOR HIGH LEVEL WINDOW NUMBERS 2710 RAMP F18 FCP WF 04 WF 33 WF 35 WF 37 SFL 9640 SFL 9640 SFL 9140 SFL 7400 SFL 9140 GATE SFL 9770 TOPPING TO BE ADDED 4 A24 4 A24 OVER OVER OVER PROVIDE OPENINGS IN PRECAST WALL FOR FUTURE DOORS. INFILL REFER SHEET A22 FOR SETOUT MALE AMENITIES F17 FSV2 FEMALE AMENITIES F15 FSV2 RETRACTABLE SEATING UNIT BELOW PROPOSED LOOSE SEATING LAYOUT BELOW SHOWN DASHED WF 39 WF 40 DF 22 FHR F19 ? V O I D TGSI TGSI TGSI TGSI HR1 HR1 BAL1 HR1 BAL1 BAL1 HR1 HR1 HR1 HR1 BSS BSS 8200 12000 SEATING BENCH SEATING BENCH TGSI TGSI MIRROR 10M LONG X 2.1M HIGH MIRROR 13.1M LONG X 2.1M HIGH 6 A32 7 A36 6 A36 CURTAIN & CURTAIN TRACK CURTAIN & CURTAIN TRACK REFER TO SERVICES DRAWINGS FOR PENETRATIONS AND PLINTHS TOPPING SLAB FALL 230 THEATRE 16690 230 DANCE STORAGE 4930 90 EXIT STAIR 7683 90 6843 90 400 1009 90 1000 90 4330 90 CORRIDOR 2000 90 DANCE STUDIO 13126 90 15 75 ACCESS 2450 90 A/LOCK 1700 90 2000 190 LIFT 2150 190 4790 90 STAFF KITCHEN & LOUNGE 4520 210 1790 90 WC 3026 90 KEYBOARD LAB 10010 90 EXISTING ROOF 90 R A M P 1 6 4 0 9 0 D A N C E S TOR A GE 7 0 6 0 9 0 9 0 S C H OOL E N TR Y 2 9 2 4 1 9 0 L IF T 2 1 1 0 1 9 0 3 9 1 0 9 0 S T AFF K ITC H E N & L OU N GE 7 7 7 0 9 0 C OR R ID OR 2 6 0 0 9 0 M AL E AM E N IITIE S 3 4 7 5 9 0 A C C W C & S H R 2 7 5 0 9 0 FE M AL E AM E N ITIE S 3 4 7 5 9 0 D AN C E STOR AGE 8 1 3 9 2 0 0 10568 17150 9616 10110 3 4 9 5 6 1 3 0 1 2 8 2 1 9 0 1 2 8 7 9 9 0 S TO R A G E 2 2 3 0 9 0 1 6 3 5 9 0 AC C E SS 2 4 5 0 9 0 A/L O C K 1 7 0 0 9 0 W C 1 2 0 0 9 0 S T AF F R OOM 6 1 5 5 9 0 9 0 1 7 1 0 9 0 DANCE S T UDIO 1 4 0 0 0 9 0 KEYBOA R D LAB 1 0 4 8 5 9 0 ST AF F R OOM 5 2 4 5 9 0 811 39 9631 7395 4104 16533 90 STORAGE 9541 90 PAC SCHOOL ENTRY 7215 90 LANDSCAPING LANDSCAPING 90 STAFF ROOM 14889 90 90 CONTROL ROOM 16798 90 HR1 LIFT G29 VOID FB FB FB FB FB FB RETAINING WALL PROVIDE SPREADER PIPES TO EXISTING MODIFIED IONA DOWNPIPES. REFER TO HYDRAULIC DRAWINGS FOR DETAILS BALUSTRADE CARPET RENDER & PAINT FINISH 20 50 RENDER & PAINT FINISH BRICKWORK LATHAM - ASBRALOY 1358ST STAIR NOSING ANTI SLIP TREATMENT HEAVY DUTY FIXINGS, 6mm MECHANICAL EXPANSION SHIELDS TYPICAL NOSING TREATMENT ALL INTERNAL AND EXTERNAL STAIRS L E G E N D PERFORMING ARTS CENTRE 3 IONA AVENUE PORT MACQUARIE, 2444 LOT 103 DP 1108613 drawing true north plotted drawn verified approved checked scale total number of sheets client project ST COLUMBA ANGLICAN SCHOOL PORT MACQUARIE, NSW revision drawing number project number c Copyright These drawings and designs and the copyright thereof are the property of DRA Architects Pty Ltd and must not be used, retained or copied without the written permission of DRA Architects Pty Ltd A.B.N. 120 9692 9387 DRA Architects Pty Ltd accept no responsibility for the usability, completeness, or accuracy of the data transferred electronically. Recipients should, when necessary, request a hard copy version for verification. Use figured dimension in preference to scale. all dimensions to be verified on site. 41 AD ACOUSTIC DOOR AGL ADJUSTABLE GLASS LOUVRE AS ACOUSTIC SEAL BAL1 BALUSTRADE TYPE 1 BAL2 BALUSTRADE TYPE 2 BOL BOLLARD BU BUILDING UNDER CC CONCRETE COLUMN CFC CEILNG FIBRE CEMENT CG CORNER GUARD CMPB CEILING MOISTURE RESISTANT PLASTERBOARD CONC CONCRETE COS CHECK ONSITE CPB CEILING PLASTERBOARD CPBP CEILING PERFORATED PLASTERBOARD CRPB CEILING RAIN NOISE BARRIER CTV CEILING TIMBER VENEER DB DOCK BUMP STOPS EGL EXISTING GROUND LINE EHD ELECTRIC HAND DRYER EX EXISTING FB FLOOR BOX FCL FINISHED CEILING LEVEL FCP FLOOR CARPET FCPM FLOOR RECESSED MAT FCS FLOOR CONCRETE FCT FLOOR CERAMIC TILE FD FIRE DOOR FG FIXED GLASS FGC FIXED GLASS COLOURED FHR FIRE HOSE REEL FML FIXED METAL LOUVRE FRL FIRE RESISTANCE LEVEL FSV1 FLOOR SHEET VINYL TYPE 1 FSV2 FLOOR SHEET VINYL TYPE 2 FSV3 FLOOR SHEET VINYL TYPE 3 FTP FLOOR PLYWOOD HR1 HANDRAIL TYPE 1 HR2 HANDRAIL TYPE 2 Mi MIRROR PTD PAPER TOWEL DISPENSOR RL REDUCED LEVEL RSF ROOFING SHEET METAL FLASHING RSM ROOFING SHEET METAL RWG1 RAIN WATER GUTTER TYPE 1 RWG2 RAIN WATER GUTTER TYPE 2 RWP1 RAIN WATER PIPE TYPE 1 RWP2 RAIN WATER PIPE TYPE 2 S/W STORMWATER SC STEEL COLUMN SD SOAP DISPENSOR SFL STRUCTURAL FLOOR LEVEL SK1 SKIRTING TYPE 1 SK2 SKIRTING TYPE 2 SK3 SKIRTING TYPE 3 SK4 SKIRTING TYPE 4 SK5 SKIRTING TYPE 5 SK6 SKIRTING TYPE 6 SS STAINLESS STEEL SSC SUN SCREENS TGSI TACTILE GROUND SURFACE INDICATES U/S UNDER SIDE VP VISION PANEL WAC WALL ALUCOBOND CLADDING WCBF WALL FACE CONCRETE BLOCK WCBP WALL CONCRETE BLOCK PAINTED WCC WALL CONCRETE COLUMN WCT WALL CERAMIC TILE WFB1 WALL FACE BRICK TYPE 1 WFB2 WALL FACE BRICK TYPE 2 WFB3 WALL FACE BRICK TYPE 3 WFC WALL FIBRE CEMENT WPB WALL PLASTERBOARD WPCP WALL PRECAST CONCRETE PAINT WPCR WALL PRECAST CONCRETE RENDER & PAINT WSMV WALL SHEET METAL VERTICAL WSV WALL SHEET VINYL WTV WALL TIMBER PANELLING CONTROLLED DOCUMENT - CHANGES WILL ADVISED Adrian Borsato NSW 4172 Warren Steele NSW 6526 ABN 12 096 929 387 PTY LTD (02) 6651 4905 dracoffs@draarchitects.com.au @B1 As indicated 1 23/12/2015 11:10:38 AM 23/12/15 23/12/15 23/12/15 FIRST FLOOR PLAN AB BS/grw 14040 A13 TENDER ISSUE AB BS/grw 1 : 100 FIRST FLOOR PLAN 1 1 : 5 INTERNAL STAIR EDGE DETAIL 3 1 : 5 STAIR NOSING DETAIL 2 rev date details initials checked 1 23/12/15 TENDER ISSUE grw AB

Articles in this issue

Archives of this issue

view archives of St Columba Anglican School - School Building Fund